Cari

  • Electromagnetic Flow Converter

    ALIA ELECTROMAGNETIC FLOW METER

    AMC2100E Series

     AMC2100E series Converter With temperature/energy function can be used with AMF series flowmeter in both compact or separate versions.

    FEATURES

     Four line LCD display Flowrate/Energy/Totalizer
     Accuracy of +/-0.4% of reading
     Bi-directional flow measurement, current and pulse output
     Large digital display, With temperature/energy function
     99 times records for power on/off
     MODBUS/HART communication

    SPECIFICATION

     
    Excitation:Keyboard:
    Square wave4 keys from external for programming 
    Display:and display control.
    4 lines LCD with backlightLow Flow Cutoff:
    Line 10 to 9.9 %
    Date and TimeDatalogger Function:
    Line 299 times records for power on/off
    6 digit flowrateRecord Data:
    7 digit energy valueDate/Time when Power on/off
    Fault code 99 years flow rate/energy/
    Supply temperatureTemperature / Total flow / Total energy
    Line 3One Record Data per Hour
    9 digit totalizer for forwarding/ reverse flowDamping:
    9 digit totalizer for heat / cold  energy0.1 to 99.9 Second
    Fault code contentSelf Diagnosis:
    Return temperatureThe following error message is 
    Line 4indicated during application
    Differential temperature– Coil fail
    Unit– Power fail
    L/S, L/M, L/H, M3/S, M3/L, M3/H– Output overaged
    KW, MW, KJ/H, MJ/H, GJ/H – Internal error
    Measuring Range:– Overflow
    Min.  0 to 0.15 m/s– Empty pipe
    Max. 0 to 15 m/sCable Entry:
    Accuracy:PG11
    +/-0.4% of reading (Velocity >= 0.5 m/s)Protection Class:
    +/-0.002 m/s (Velocity < 0.5 m/s)IP 65
    Repeatability:Ambient Temperature:
    +/-0.1% of reading-25 to +65 oC
    Current Output:Material:
    4-20 mA (Isolated)Aluminum Alloy
    LoadTemperature Input:
    Max. 600 PT1000, 2 wire 
    Pulse output:Power Supply:
    Open collector90-260 VAC, 50/60 Hz
    Rating24 VDC +/- 10% (Option)
    3 to 30 VDC, 20 mA Max. Power Consumption:
    Pulse Rate:3-17 W (depending on the sensor size)
    1)Scale pulse, (Pulse/M3, Pulse/L,
     Other)
    Weight:
    2)Frequency, 0-5000 Hz1.4 Kg
    Communication:Mounting:
    RS 485(MODBUS Protocol)Wall mounting
    HART signalBracket on 2″ pipe
    Data Storage:
    Operation parameters and totalization 
    figures are stored by EEPROM for more than 10 years
  • Entri Populer

    Entri yang Diunggulkan

    JASON INDUSTRIAL

    Founded in 1958 in Fairfield, NJ, Jason Industrial quickly gained a solid reputation as a go to source for both industrial hose and power tr...