    Mass Flow Controller/Mass Flow Meter With Indicator

    Kofloc MODEL D8500 SERIES

    Kofloc mass flow controller/meter driven by a 24 VDC power supply has been developed as a successor to the MODEL 8300. The viewpoint change function of the display unit and the pattern setting function are unique to this model, and noise resistance has been improved dramatically. A sister model with a detachable display and setting unit is also available.

    Features :

    • The high-lift actuator allows this compact model to control a large flow rate.
    • Equipped with a display and setting unit, this model can be operated by a 24 VDC power supply
    • The RS232C/RS485 communication function and integration function are provided as standard equipment.
    • The 14-bit  converter permits to display and operation in 4-1/2 digits.
    • Control of the flow rate of inflammable gas is possible because the heat generating part of the sensor is not exposed to the gas.
    • There are no limitations on the mounting position that may be employed
    • In addition to the SV setting, five other patterns can be set.
    • Auto zero and auto close functions are also standard.

    Standard Specifications :

    • Flow range (F.S.) (at N2 calibration conditions) : 50 SCCM-5 SLM
    • Applicable gases (dry gas): N2, air, O2, CO2, Ar, H2, He, etc.
    • Sensor: a Thermal mass flow sensor
    • Valve actuator: Normally-closed solenoid valve actuator *7
    • Valve type: Poppet valve *7
    • Control System :
      • Control/measurement range  : 2-100% F.S.
      • Response: 0-100% F.S. or more within 2 sec. *1
      • bellow 10% F.S. within 4 sec. *
    • Accuracy :
      • Flow accuracy: ±1.0%F.S. *2
      • Repeatability: ±0.75%F.S.
    • Pressure :
      • Proof pressure: 1000 kPa (G)
      • Allowable operating pressure: 500 kPa (G) or less
      • Operating differential pressure *7 : 50–300 kPa (G) =>  100-300 kPa (G)
    • Temperature :
      • Allowable operating temperature: 5–45℃
      • Temperature characteristics : 0.2% F.S./℃
    • Humidity :
    • a). Allowable operating humidity: 10–90% (No condensation allowed)
    • Leak: He leak rate: 1 × 10-8 Pa•m3/sec. or less *3
    • Flow setting method:
      • Digital :
        • Setting & display unit
        • Communications
        • Event input selection
      • Analog *7 : (1) 0–5 V (2) 4–20 mA (freely selectable)
      • Flow rate output:
        • Analog : (1) 0-5 V (2) 4-20 mA (interlocked with the above)
    • Display :
      • Display format: 7-segment 4-digit LED
      • Total flow: 12 digits *4
      • Mounting direction: Changeable
      • Built-in/Separate :Built-in, separate 1 m, separate 3 m, separate 5 m
      • Status display LED : OK (within allowable range), ALM (alarm output interlock) OUT1 (event output 1 interlock), OUT2 (event output 2 interlock) SV (set flow), PV (instantaneous flow), TF (total flow) IF (mode setting)
    • Other I/O functions :
      • Event input : 3 × contact input
      • Alarm output: 1 × open collector output, Max. 35 V, 50 mA
      • Event output: 2 × open collector output Max. 35 V, 50 mA
      • Communications: RS-485, half-duplex, 9600 bps
    • Power supply :
      • Rating : 24 VDC, current consumption: 300 mA max.
      • Allowable supply voltage range: 21.6–26.4 VDC (Ripple: 5% or less)
    • Mounting position: Not specified
    • Applicable standards: RoHS and EN62326-1: 2006
    • Materials of parts in contact with gases: SUS316, SUS316L, SUS430, FKM, PTFE, chloroprene rubber (option)
    • Joint: 1/4 SWL, RC1/4, 1/4 VCR
    • Weight :
      • Built-in: Approx. 1000 g
      • Separate (excluding the cable): Approx. 1200 g (*6)