Cari

  • Kofloc High Grade Mass Flow Controllers Model 5100 Series

    High-Grade Metal Flow Controllers

    MODEL 5100 SERIES

    Model 5100 Series Mass Flow Controller/Meter features weldless structure, metal seals, the accuracy of ≤±1%, the response of ≤±1 second and other basic performance conditions required for semiconductor process control, and additionally, has achieved a significant price reduction.

    Features

    – High accuracy and high response are achieved by the flow sensors with temperature- following current difference detection.
    – A normally-closed solenoid valve is employed.
    – A low leak rate is achieved by the weldless structure and metal seal.
    – The dead volume is reduced thanks to the diaphragm seat valve.-
    – The face-to-face and body dimensions and the wiring tie-in points are designed to facilitate the replacement of devices made by other companies.

    Standard Specifications

    -Flow range(N2 equivalents, 06 ℃/1 atm): 1 SCCM – 20 SLM (The conditions are freely selectable) -Sensor: Thermal mass flow sensor
    -Valve type: Proportional solenoid valve (closed when not energized)
    -Control range: 2 – 100% (Porto)
    -Response: 1 sec. or less (0 – 100% within ± 2% typical)
    -Accuracy: ± 1% of Porto (Accuracy guaranteed at 15-35 ℃)
    -Repeatability: ± 0.2% of Porto
    -Operating differential pressure port:
    * ≤ 5 SLM: 50 – 300 kPa
    * Porto 5 > SLM: 100 – 1000 kPa
    * Option: Low differential pressure (LP) specification is available depending on conditions.
    -Allowable operating pressure: 300 kPa (G) or less
    – Pressure-Proof: 980 kPa (G)
    -Leak rate: 1 × 10-11 Pa • m3/s or less
    -Allowable ambient temperature: 0-50 ℃
    -Allowable ambient humidity: 10 & ndAsh; 90% (No condensation allowed)
    -Materials of the parts in contact with gases:
    * Body: SUS316L
    * Diaphragm:
    * Valve seat: PTFE
    * Sealing: SUS316L, Ni, Au
    * Option: SUS seal (SU), inner surface polish (KP)
    -Electric connection: 9-pin Dsub connector as per Standard KFC (Compliant with SEMI Standard)
    -Flow rate input signals: 0-5 VDC (Input impedance: 1 MΩ or more)
    -Flow rate output signals: 0-5 VDC (External load resistance: 250 kΩ or more)
    -Required power supply: +15 VDC (±5%) 100 mA, −15 VDC (±5%) 200 mA
    – Joint (Main unit bore) : Standard: 1/4 VCR equivalent Option: 1/4 SWL
    – Weight: Approx. 1000 g