Cari

  • Seametrics PT12-BV Barometric and Vacuum Sensor

    Seametrics PT12-BV

    Feature
  • Weatherproof box

  • Automatic barometric compensator

  • SDI-12 v1.3 interface and/or Modbus® RTU interface (Depends on version)

  • Pressure/vacuum and temperature

  • Polyethylene, polyurethane, and ETFE cable options

  • The Seametrics PT12-BV comes as a weatherproof stand-alone box or with an automatic compensation wiring option. The PT12-BV measures pressure, temperature, and supply voltage.
    The weatherproof box is an ideal barometric reference for absolute pressure sensors. This version features both an SDI-12 interface and a Modbus® RTU interface that makes the product easy to connect to recorders and operates on low power. This makes it a preferred choice for many environmental professionals with existing SDI-12 or Modbus® RTU systems.
    With the Compensation Wiring Option, the PT12-BV automatically provides barometric compensation for a single attached absolute PT12 submersible pressure sensor. No post-processing of data. No need to use a vented cable or worry about maintaining desiccant tubes. This version features an SDI-12 communication interface, making it ideal for many existing environmental systems.

    Application

    • Barometrically compensate for absolute pressure sensors for level measurement
    • Measure vacuum pressure during vapor extraction pilot testing
    • Supplement aquifer test data in leaky or confined conditions
    • Measure accurate barometric pressure
    Another Article:

    Specification

    HousingMaterialWeatherproof box – ABS – IP66/67
    DimensionsBox only: 4.3” x 3.1” x 2.5” (10.9 x 7.9 x 6.4 cm)
    Wire Seal MaterialFluorocarbon and Buna N
    Communication Pigtail5 ft (1.5 m) polyurethane cable
    OptionsPT12-BV compensation wiring option; Bulkhead connector
    TemperatureOperating RangeRecommended: -15 ̊ to 55 ̊C (5 ̊ to 131 ̊F) Not designed to operate under water
    Storage Range-40 ̊ to 80 ̊C (-40 ̊ to 176 ̊F)
    PowerVoltage9-16Vdc, 24Vdc over voltage protection, electromagnetic & transient protection IEC-61000 – 4-3, 4-4, 4-5, 4-6
    Supply CurrentActive 3mA average/ 10mA peak; sleep 150 μA
    CommunicationModbus®RS485 Modbus® RTU, output=32bit IEEE floating point
    SDI-12SDI-12 (ver. 1.3) – ASCII
    Output ChannelsTemperatureDepth/Level
    ElementDigital IC on boardSilicon strain gauge transducer, 316 stainless
    Accuracy±0.5°C — 0° to 55°C (32 ̊ to 131 ̊F)
    ±2.0°C — below 0°C (32 ̊F)
    ±0.05% FSO (typical, static)
    ±0.1% FSO (maximum, static)
    (B.F.S.L. 20 ̊C)
    Resolution0.06 ̊C0.0034% FS (typical)
    Range-15 ̊ to 55 ̊C (5 ̊ to 131 ̊F)0-16 psia (110 kpa)
    Compensated0 ̊ to 40 ̊C (32 ̊ to 104 ̊F)
    Over pressure protection2x
    EnvironmentalIP66/67
    *Specifications subject to change. Please consult out a web site for the most current data (seametrics.com). Modbus is a registered trademark of Schneider Electric.
    For further information please contact : marketing@wmablog.com