Cari

  • Seametrics PT12 Pressure & Temperature with Modbus & SDI-12 Interface

    Simetrics PT12

  • Small diameter — 0.75” (1.9 cm)

  • Pressure and temperature

  • 316 stainless steel, fluoropolymer, and PTFE construction (titanium optional)

  • Polyethylene, polyurethane, and ETFE cable options

  • End code interchangeable with a 1/4” NPT inlet

  • Specification per OSW Technical Memo 96.05 is an option on the 15 PSIG (10.5 mH₂O) and 30 PSIG (21 mH₂O) units

  • The Seametrics PT12 Pressure/Temperature Sensor has been designed to provide trouble-free submersible operation in liquid environments. This sensor communicates via SDI-12 (v1.3) or Modbus® RTU (RS485)protocol.
    Pressure/level is measured with an extremely rugged and stable piezo-electric, media isolated pressure element and compensated for temperature using our proprietary calibration methodology. Temperature is measured using an on-board digital chip.
    Seametrics also carries a special version of the PT12 designed to measure barometric pressure in reference to absolute pressure. If you are using an absolute PT12, contact your representative for details on how our PT12-BV can facilitate obtaining barometrically compensated pressure/level.

    Application

    • Rugged construction can replace analog sensors
    • Monitor groundwater, well, tank, and tidal levels
    • Pump testing
    • Flow monitoring
    Another Article:

    Specification

    Housing & CableWeight0.8 lb. (0.4 kg)
    Body Material316 stainless or titanium
    Wire Seal MaterialFluoropolymer and PTFE
    CableSubmersible: polyurethane, polyethylene, or ETFE; 4 lb./100 ft., 1.8 kg/30 m; 2000 ft max for Modbus®
    Desiccant1-3 mm indicating silica gel
    Field ConnectorAvailable as an option
    TemperatureOperating RangeRecommended: -15 ̊ to 55 ̊C (5 ̊ to 131 ̊F) Requires freeze protection kit if using pressure option in the water below freezing.
    Storage Range-40 ̊ to 80 ̊C (-40 ̊ to 176 ̊F)
    PowerVoltage9-16Vdc, 24Vdc over voltage protection, electromagnetic & transient protection IEC-61000 – 4-3, 4-4, 4-5, 4-6
    Supply CurrentActive 3mA average/ 10mA peak; sleep 150 μA
    CommunicationModbus®RS485 Modbus® RTU, output=32bit IEEE floating point
    SDI-12SDI-12 (ver. 1.3) – ASCII
    Output ChannelsTemperatureDepth/Level
    ElementDigital IC onboardSilicon strain gauge transducer, 316 stainless or Hastelloy
    Accuracy±0.5°C — 0° to 55°C (32 ̊ to 131 ̊F)
    ±2.0°C — below 0°C (32 ̊F)
    ±0.05% FSO (typical, static)
    ±0.1% FSO (maximum, static)
    (B.F.S.L. 20 ̊C)
    Resolution0.06 ̊C0.0034% FS (typical)
    UnitsCelsius, Fahrenheit, KelvinPSI, FtH₂O, inH₂O, mmH₂O, mH₂O, inH₂O, cmHg, mmHg, Bars, Bars, kPa
    Range-15 ̊ to 55 ̊C (5 ̊ to 131 ̊F)GaugePSI: 1², 5, 7, 15, 30, 50, 100, 300
    FtH₂O: 2.3², 12, 35, 69, 115, 231, 692
    mH₂O: 0.7², 3.5, 5, 10.5, 21, 35, 70, 210
    Absolute²PSI: 30, 50, 100, 300
    FtH₂O: 35, 81, 196, 658
    mH₂O: 10, 24, 59, 200
    Compensated0 ̊ to 40 ̊C (32 ̊ to 104 ̊F)
    Max operating pressure1.1 x full scale
    Overpressure protection3x full scale up to 300psi – for > 300psi (650 ft or 200 m) contact factory
    Burst pressure1000 psi (approx. 2000 ft or 600 m)
    EnvironmentalIP68, NEMA 6P
    *Specifications subject to change. Please consult our web site for the most current data (seametrics.com). Modbus is a registered trademark of Schneider Electric.
    1 Higher pressure ranges available upon request
    2 ±0.25% accuracy FSO (max) at this range
    3 The depth range for absolute sensors has 14.7 PSI subtracted to give actual depth allowed.
    For further information please contact : marketing@wmablog.com