  • Kofloc D8500 Series Mass Flow Meter

    D8500 mass flow controller/meter driven by a 24 VDC power supply has been developed as a successor to the MODEL8300.
    The viewpoint change function of the display unit and the pattern setting function are unique to this model, and noise resistance has been improved dramatically. A sister model with a detachable display and setting unit is also available.

    Features

    • The high-lift actuator allows this compact model to control a large flow rate.
    • Equipped with a display and setting unit, this model can be operated by a 24 VDC power supply.
    • The RS232C/RS485 communication function and integration function are provided as standard equipment.
    • The 14-bit converter permits to display and operation in 4-1/2 digits.
    • Control of the flow rate of inflammable gas is possible because the heat generating part of the sensor is not exposed to the gas.
    • There are no limitations to the mounting position that may be employed.
    • In addition to the SV setting, five other patterns can be set.
    • Auto zero and auto close functions are also standard.
      Another Article:

    Specification

    Sensor typeThermal sensor
    Valve typeNormally closed solenoid valve
    Applicable gases*1N2, Air, H2, He, Ar, O2, CO2, etc.
    Gases not specifically mentioned here are subject to calibration for N2 equivalent.)
    Flow range*250 SCCM to 5 SLM and Over 5 SLM-20 SLM
    Control range2 to 100% (F.S.)
    Response*30–100% F.S. or more within 2 sec. *1
    0–below 10% F.S. within 4 sec. *1
    Accuracy*4±1.0%F.S. *2 (50 SCCM to 5 SLM) and ±1.5%F.S. *2(Over 5 SLM-20 SLM)
    Repeatability±0.75%F.S.
    Operating differential pressure*550–300 kPa (G) (50 SCCM to 5 SLM) and 100–300 kPa (G)(Over 5 SLM-20 SLM)
    Inlet maximum pressure500kPa(G)or less
    Proof pressure1000kPa(G)
    External leak rate1.0 x 10-8 Pa·m3/sec or less *3
    TemperatureWorking temp.5 to 45℃
    Allowable operating humidity10 to 90% RH (without dew condensation)
    Materials of the gas contact partSUS316L, PTFE, and magnetic stainless steel
    Electrical connectionD-sub 9-pin, KFC standard (SEMI standard compliant), RJ-45 modular jacks (two)
    Flow rate setting signal0 to 5 V DC (input impedance approx. 1 MΩ)
    Flow rate output signal0 to 5 V DC (load resistance 10 KΩ)
    Digital communicationAddress setting with RS485 rotary switch: up to 99 devices (9600 bps)
    Required power supply (DC)+15 V DC (±5%), 150 mA; -15 V DC (±5%), 150 mA
    Joint1/4 SWL, RC1/4, 1/4 VCR
    Mounting postureNot specified
    WeightApprox. 1000 g
    (*1) The time required to reach the control flow ±2% F.S. from the fully closed state
    (*2) With the standard pressure of 200 kPa (G) and the standard temperature of 20℃
    (*3) Permeation is not included. The leakage by prolonged permeation shall not exceed 1 × 106 Pa・m3/sec.
    (*4) The units of measurement vary with the full-scale flow. E.g.: With 1 SLM, the flows can be added up to 9999 9999 9.999 L.
    (5) For other joints, please contact us. (6) The weight may slightly vary depending on the joint. (*7) These apply to the D8500MC mass flow controller.
    For further information please contact : marketing@wmablog.com